Intermittent Temperature Control Fault
Freezer temperature fluctuates widely; sometimes too warm, sometimes too cold
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose connection at temperature sensor, Intermittent main PCB fault, Poor door seal causing variable load, Fan motor intermittently stopping
How to Fix / Troubleshooting
Safety: Unplug before accessing internal wiring or PCB.
Steps to stabilise temperature:
- 1. Check door seal and usage: Ensure the door is not frequently left ajar and that the gasket seals well.
- 2. Inspect sensor connections: Access the cabinet NTC sensor and verify that its connector is tight and wiring undamaged.
- 3. Monitor fan operation: Confirm that the evaporator fan runs whenever the compressor is on and the door is closed. Replace the fan if it stops intermittently.
- 4. PCB inspection: Look for dry joints or loose connectors on the main PCB. Reseat connectors.
Note: If fluctuations persist despite these checks, the PCB or sensor may need replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Cabinet NTC Temperature Sensor