AL
Costway General Alarm (Temperature or Door)

Display shows AL and an audible alarm sounds intermittently.

Advertisements

Possible Causes

Door left open too long, High temperature condition, Faulty door switch not detecting closure

How to Fix / Troubleshooting

Safety: No internal electrical work is needed for basic checks. Unplug the unit before testing switches with tools.

Steps to clear AL:

  • Confirm door closure: Close the door firmly and ensure nothing is blocking it. Check that the gasket contacts the cabinet all around.
  • Check door switch: Locate the door switch (usually at the top or side of the opening). Press it by hand; the interior light should turn off and the alarm may silence.
  • Clean the switch area: Wipe away frost or debris that may prevent the switch from fully depressing.
  • Test the switch (if needed): Unplug the freezer, remove the switch (often held by a clip or screw), and test continuity with a multimeter while pressing and releasing the button. Replace if it does not change state.
  • Allow temperature to recover: If the door was left open, give the freezer several hours to cool back down. The alarm will usually clear automatically.

Note: If AL persists with a closed door and good temperature, the control board or sensor may be misreading and require professional diagnosis.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Switch
Check Price on Amazon

We may earn a commission from links on this page.