Costway Interior Light Circuit Failure

Freezer interior light does not turn on when door is opened, but cooling is normal.

Advertisements

Possible Causes

Burnt LED or bulb, Faulty door switch, Loose light connector

How to Fix / Troubleshooting

Safety: Unplug the freezer before replacing bulbs or accessing wiring.

Steps to restore interior light:

  • Check door switch: Press the door switch by hand with the door open. If the light flickers or comes on intermittently, the switch may be faulty.
  • Test the switch: Remove the switch and test continuity with a multimeter while pressing and releasing. Replace if it does not change state.
  • Inspect the light module: Remove the light cover (usually snaps off). Check for loose connectors or burnt LED/bulb.
  • Replace light source: Install a compatible Costway freezer LED light module or bulb. Do not exceed the specified wattage if using an incandescent bulb.
  • Reassemble and test: Restore power and open the door to confirm the light operates correctly.

Note: If both the switch and light module are good, the control board output to the light may be faulty and require replacement.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Switch or LED Light Module
Check Price on Amazon

We may earn a commission from links on this page.