Danby General Alarm Condition (Temperature or Door)

Danby freezer shows AL or an alarm icon and beeps intermittently.

Advertisements

Possible Causes

Door left open, High temperature condition, Faulty door switch, Failed temperature sensor causing false alarm

How to Fix / Troubleshooting

Safety first: Ensure the door is closed to prevent condensation and slipping hazards.

Steps to address AL/alarm:

  • Check door closure: Confirm the door is fully closed and not obstructed by food items or shelves.
  • Inspect door gasket: Look for tears, gaps, or debris preventing a tight seal. Clean the gasket and cabinet mating surface.
  • Test door switch: Locate the door switch (usually near the top front frame). Press it manually; the interior light should turn off and the alarm may silence. If not, the switch may be faulty.
  • Replace door switch: If the switch does not change state when pressed, replace the door switch.
  • Check temperature: Use a thermometer to verify actual freezer temperature. If warm, follow high-temperature troubleshooting (fan, compressor, condenser cleaning).

Note: Some models allow muting the alarm temporarily via the control panel, but the underlying cause should still be corrected.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Switch