Danby
Control or Thermostat Malfunction
Freezer cycles on and off rapidly or randomly; temperature fluctuates widely.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty electronic control board, Defective temperature sensor, Loose sensor connection, Power supply fluctuations
How to Fix / Troubleshooting
Safety first: Unplug the freezer before accessing the control panel or wiring.
Steps to stabilize cycling:
- Check power quality: Avoid using extension cords or power strips. Plug directly into a properly grounded outlet.
- Inspect temperature sensor: Locate the cabinet sensor and ensure it is firmly mounted and not touching extremely cold surfaces. Check wiring for damage.
- Test sensor: Measure resistance and compare to expected values. Replace the cabinet temperature sensor if readings are unstable or out of range.
- Control board replacement: If the sensor is good but the compressor and fan cycle erratically, replace the main control board.
Note: Some cycling is normal as the unit maintains temperature, but rapid short cycling can damage the compressor over time.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Cabinet Temperature Sensor (NTC Probe)