Danby
Stratified Air / Partial Airflow Restriction
Freezer interior temperature too warm only at the top; bottom baskets stay frozen.
Advertisements
Possible Causes
Evaporator fan running slowly, Air ducts partially blocked by ice or packaging, Shelves or baskets blocking vents, Poor loading pattern
How to Fix / Troubleshooting
Safety first: Unplug the freezer before removing panels or clearing ice.
Steps to improve top compartment cooling:
- Check fan operation: Ensure the evaporator fan runs at full speed when the compressor is on. Replace the evaporator fan motor if weak or intermittent.
- Inspect air vents: Locate supply and return vents in the liner and clear any ice or packaging blocking them.
- Reorganize contents: Avoid stacking items directly in front of vents or packing the top shelf too tightly.
- Defrost if needed: If ice is blocking airflow channels, perform a manual defrost to restore proper circulation.
Note: Upright freezers rely heavily on unobstructed airflow to maintain even temperatures.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Evaporator Fan Motor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements