Danby Stratified Air / Partial Airflow Restriction

Freezer interior temperature too warm only at the top; bottom baskets stay frozen.

Advertisements

Possible Causes

Evaporator fan running slowly, Air ducts partially blocked by ice or packaging, Shelves or baskets blocking vents, Poor loading pattern

How to Fix / Troubleshooting

Safety first: Unplug the freezer before removing panels or clearing ice.

Steps to improve top compartment cooling:

  • Check fan operation: Ensure the evaporator fan runs at full speed when the compressor is on. Replace the evaporator fan motor if weak or intermittent.
  • Inspect air vents: Locate supply and return vents in the liner and clear any ice or packaging blocking them.
  • Reorganize contents: Avoid stacking items directly in front of vents or packing the top shelf too tightly.
  • Defrost if needed: If ice is blocking airflow channels, perform a manual defrost to restore proper circulation.

Note: Upright freezers rely heavily on unobstructed airflow to maintain even temperatures.