Danby Partial Sealed System Restriction or Low Charge

Frost-free Danby freezer has ice buildup only on one corner of the evaporator coil.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Refrigerant leak, Capillary tube restriction, Weak compressor, Factory charge loss over time

How to Fix / Troubleshooting

Safety first: Do not attempt to cut or open refrigerant lines yourself.

Steps to evaluate partial frost pattern:

  • Observe frost: After 10–20 minutes of run time, inspect the evaporator. If only a small section frosts while the rest remains bare, a sealed system issue is likely.
  • Check fans and defrost: Confirm the evaporator fan runs and defrost system is not stuck on. If these are normal, the problem is within the sealed system.
  • Professional service: Contact a licensed refrigeration technician to check for leaks, measure pressures, and repair or recharge the system.

Note: Sealed system repairs can be costly; consider the age and value of the freezer before proceeding.

Advertisements

Repair Difficulty

Professional Required 5/5