AL08
De Dietrich Door Switch / Door Contact Fault

Freezer displays AL08; door alarm may not behave correctly or interior light stays on.

Advertisements

Possible Causes

Faulty magnetic door switch, Misaligned door magnet, Broken door switch wiring, Control board input fault

How to Fix / Troubleshooting

Safety first: Unplug the freezer before removing trims or switch housings.

  • Check door closure: Ensure the door closes fully and is not warped. Look for items preventing full closure.
  • Locate door switch: Some De Dietrich freezers use a mechanical plunger switch in the frame; others use a magnetic reed switch hidden in the cabinet with a magnet in the door.
  • Test the switch: For a plunger switch, press it by hand with the door open and see if the interior light goes off. For a magnetic system, hold a strong magnet near the switch area and see if the alarm stops.
  • Inspect wiring: Remove the switch (if accessible) and check for loose or corroded connectors. Repair or replace damaged wiring.
  • Replace faulty switch: Install a compatible De Dietrich door switch or magnet assembly if the original is defective.
  • Reset alarm: After reassembly, plug in the freezer and confirm that AL08 clears and the door alarm/light now operate normally.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Switch / Reed Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements