AL11
De Dietrich Fan Speed / Feedback Fault

Freezer shows AL11; internal fan may run at incorrect speed or not at all, even though no ice is present.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Evaporator fan with tachometer feedback failure, Damaged fan harness, Faulty fan driver circuit on PCB, Obstruction in fan housing

How to Fix / Troubleshooting

Safety first: Disconnect power before accessing the fan or control board.

  • Check for obstructions: Remove baskets and the internal rear panel. Ensure nothing is blocking the fan blades and that the shroud is correctly positioned.
  • Inspect fan motor: Many De Dietrich fans have a feedback (tach) wire. Check the connector for corrosion or loose pins. Gently tug each wire to ensure it is secure.
  • Replace fan if faulty: If the fan does not run when powered and wiring is intact, replace it with the correct De Dietrich evaporator fan motor with tach feedback.
  • Check PCB connector: At the main board, reseat the fan connector. Look for burnt or cracked solder joints at the fan driver components.
  • Test operation: Reassemble, restore power, and verify that the fan runs smoothly and AL11 clears.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Evaporator Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements