Electrolux Sensor Out-of-Range / Display Fallback

Display shows dashes or blank temperature instead of a numeric value, but no explicit error code.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Disconnected or failed temperature sensor, Broken sensor harness, Control board unable to read sensor, Extreme internal temperature beyond display range

How to Fix / Troubleshooting

Safety first: Unplug the freezer before accessing sensors or the control board.

  • 1. Confirm actual temperature: Use a thermometer to check internal temperature. If extremely high or low, address cooling or overcooling issues first.
  • 2. Inspect sensor connections: Locate the cabinet temperature sensor and ensure its connector is fully seated and wires are intact.
  • 3. Test sensor resistance: Measure resistance and compare to the NTC chart. Replace if open, shorted, or out of range.
  • 4. Check harness continuity: Test wiring from sensor to control board and repair any breaks.
  • 5. Replace control board: If sensor and wiring are good but display still shows dashes, replace the main control board.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Cabinet NTC Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.