E9
Electrolux
Door Switch / Door Sensor Fault
Freezer shows E9; door alarm may sound continuously even when door is closed.
Advertisements
Possible Causes
Defective magnetic door switch or reed sensor, Misaligned door or weak door magnet, Broken door switch wiring, Faulty input on main control board
How to Fix / Troubleshooting
Safety first: Unplug the freezer before testing or replacing the door switch.
- 1. Locate the door switch: On Electrolux freezers, the door switch is usually in the door frame or integrated into the liner near the top.
- 2. Check door alignment: Ensure the door closes fully and the gasket makes uniform contact. Adjust hinges if the door is sagging.
- 3. Test the switch: Remove the switch or access its connector. With a multimeter, test continuity while pressing and releasing the switch (or moving the magnet near a reed sensor). Replace if it does not change state reliably.
- 4. Inspect wiring: Check for broken or pinched wires between the switch and control board.
- 5. Replace control board if needed: If the switch and wiring are good but E9 persists, the control board input may be defective and require replacement.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Door Switch / Door Sensor
Check Price on Amazon