Electrolux Poor Cooling / Loss of Capacity

Freezer runs but does not get cold enough; temperature is higher than setpoint, compressor runs almost constantly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Dirty condenser coils, Failed condenser fan motor (if equipped), Low refrigerant charge from leak, Weak compressor

How to Fix / Troubleshooting

Safety first: Unplug the freezer before cleaning coils or accessing the compressor compartment.

  • 1. Check door seal: Ensure the door gasket seals all around. Replace if torn or warped.
  • 2. Clean condenser coils: On Electrolux freezers, coils may be on the back or underneath. Use a coil brush and vacuum to remove dust and lint. Ensure airflow is not blocked by wall or clutter.
  • 3. Verify condenser fan operation: If your model has a condenser fan near the compressor, confirm it runs whenever the compressor runs. Replace the condenser fan motor if it does not start or is noisy.
  • 4. Inspect frost pattern: Remove the interior rear panel and check the evaporator. A partial frost pattern (only at the inlet) suggests a sealed system issue requiring a professional.
  • 5. Allow time to stabilize: After cleaning and corrections, allow 12–24 hours for temperature to stabilize before judging performance.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Condenser Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements