AL09
Fagor Door Switch / Door Sensor Fault

Freezer shows AL09; door alarm may sound continuously even when door is closed.

Advertisements

Possible Causes

Defective magnetic door switch, Misaligned door or hinge, Broken wiring to door switch, Faulty input circuit on control board

How to Fix / Troubleshooting

Safety first: Disconnect power before removing trims or accessing the door switch wiring.

  • Check door closure: Ensure the Fagor freezer door closes fully and is not obstructed by baskets or food. Adjust shelves if necessary.
  • Inspect gasket and hinges: Look for twisted or damaged door gasket and sagging hinges that prevent proper closure. Adjust or replace hinges if the door is misaligned.
  • Locate door switch: Depending on the model, the door switch may be a plunger switch in the frame or a magnetic reed sensor hidden in the cabinet. Inspect for physical damage.
  • Test switch: With the freezer unplugged, remove the switch and test continuity with a multimeter while pressing it. Replace the Fagor door switch if it does not change state reliably.
  • Magnetic sensor check: For magnetic systems, ensure the door magnet is present and aligned with the sensor area. Replace missing magnets or sensor assemblies.
  • Control board: If the switch tests good but AL09 persists, the control board input may be faulty and require replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Switch Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements