E5
Fagor
High Temperature / Sensor Calibration Error
Display shows E5; alarm may sound; temperature display may flash.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Misreading temperature sensor, Poor sensor contact with evaporator, Control board calibration fault, Partial refrigerant loss causing high temperature
How to Fix / Troubleshooting
Safety first: Unplug the freezer before removing panels or touching internal components.
- Check door and load: Ensure the door is closing properly and the freezer is not overloaded. Allow several hours after large food loads.
- Verify sensor placement: Access the evaporator and confirm the Fagor sensor is correctly clipped to the coil or in its designated well. Reattach if loose.
- Inspect for frost pattern: A partial frost pattern (ice only on part of the evaporator) may indicate a sealed system issue, which requires professional service.
- Replace sensor if needed: If the sensor appears damaged or gives inconsistent readings, replace it with an OEM Fagor NTC sensor.
- Control board: If temperature is actually correct but E5 persists, the control board may be misreading the sensor and should be replaced.