F2
Fagor Thermostat / Sensor Out-of-Range Error

Freezer shows F2; compressor may run continuously; temperature may be too low.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted temperature sensor, Sensor wires shorted together, Control board misreading sensor, Incorrect replacement sensor installed

How to Fix / Troubleshooting

Safety first: Disconnect power before accessing sensors or the control board.

  • Inspect sensor wiring: Locate the cabinet NTC sensor and check for crushed or exposed wires that could be shorting.
  • Measure resistance: With a multimeter, check sensor resistance at room temperature. A very low value (near 0 Ω) indicates a shorted sensor. Replace with the correct Fagor NTC sensor.
  • Verify part number: Ensure any previously replaced sensor matches the original Fagor specification.
  • Control board: If sensor and wiring are correct but F2 persists, the control board analog input may be faulty and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Cabinet NTC Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.