F5
Fagor
Ambient Sensor / Environment Error
Freezer shows F5; alarm may sound; temperature may be unstable.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Ambient sensor out of range, Freezer installed in very hot or very cold room, Sensor wiring fault, Control board misinterpretation
How to Fix / Troubleshooting
Safety first: Unplug the freezer before accessing the control panel or sensor wiring.
- Check installation location: Ensure the Fagor freezer is not installed in a garage or unheated space outside the specified ambient temperature range.
- Inspect ambient sensor: Locate the ambient NTC sensor near the control panel or front grille and check for damage.
- Measure resistance: Test the sensor at room temperature and replace if readings are out of specification.
- Relocate appliance: If the room is too hot or cold, move the freezer to a more suitable location.
- Control board: Persistent F5 with a good sensor and proper environment may indicate a faulty control board.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Ambient NTC Sensor