Fagor Drawer Icing / Mechanical Obstruction

Freezer baskets or drawers difficult to slide; ice buildup around rails.

Advertisements

Possible Causes

High humidity entering through door, Door left ajar, Defrost water refreezing on rails, Damaged drawer rails

How to Fix / Troubleshooting

Safety first: Unplug the freezer before using heat to remove ice.

  • Defrost rails: Remove drawers and use warm water or a hair dryer on low to melt ice from the Fagor drawer rails and supports.
  • Dry thoroughly: Wipe all surfaces dry before reinstalling drawers.
  • Check door seal: Ensure the door closes fully and the gasket is intact to reduce moisture ingress.
  • Replace damaged rails: If rails are bent or broken, replace them with OEM Fagor drawer rail assemblies.
Advertisements

Repair Difficulty

Very Easy 1/5

Required Part

Drawer Rail Kit
Check Price on Amazon