Frigidaire Poor Air Circulation

Freezer interior temperature is uneven; top is warm while bottom is very cold (upright models).

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Evaporator fan not running, Air vents blocked by food, Frost buildup on evaporator, Fan blade damaged or loose

How to Fix / Troubleshooting

Safety First: Unplug the freezer before removing interior panels or working near the fan.

  • Step 1 – Check loading: Ensure food items are not blocking air vents at the back or top of the freezer.
  • Step 2 – Verify fan operation: Press the door switch to simulate a closed door and listen for the evaporator fan. If silent, test and replace the fan motor.
  • Step 3 – Inspect for frost: Remove the rear interior panel and check for heavy frost on the evaporator. If present, troubleshoot the defrost system.
  • Step 4 – Fan blade: Confirm the blade is secure on the motor shaft and not broken. Replace if needed.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Evaporator Fan Motor
Check Price on Amazon