GE Profile Continuous Run – High Duty Cycle

Freezer runs constantly and rarely shuts off

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Door gasket leak, Dirty condenser coils, Evaporator fan not running, Low refrigerant charge

How to Fix / Troubleshooting

Safety first: Unplug the freezer before cleaning or accessing fans.

  • Check door seal: Look for frost around the door opening, which indicates air leaks. Clean and inspect the gasket; replace if damaged.
  • Clean condenser: Vacuum and brush the condenser coils to improve heat rejection.
  • Verify evaporator fan: Open the door, press the door switch, and listen for the fan. If silent, inspect and replace the evaporator fan motor as needed.
  • Ambient temperature: Ensure the freezer is not in a very hot or unventilated space, which can cause long run times.
  • Professional check: If all above are good and the unit still runs constantly without reaching set temperature, a sealed system issue may exist and requires a technician.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Evaporator Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements