Gladiator Condenser Fan Failure

Condenser fan at the back of the freezer is not running, and compressor is very hot.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed condenser fan motor, Obstruction in fan blades, Open fan wiring, Faulty control board fan output

How to Fix / Troubleshooting

Safety First: Unplug the freezer before accessing the rear compartment. The compressor and lines may be hot.

  • Step 1 – Inspect fan: Remove the rear access panel. Check if the condenser fan blade is blocked by debris. Clear any obstruction.
  • Step 2 – Spin test: With power off, spin the fan by hand. If stiff or seized, replace the condenser fan motor.
  • Step 3 – Electrical test: Check for voltage at the fan motor terminals when the compressor is running (advanced). If voltage is present but fan does not run, replace the motor. If no voltage, suspect the control board.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Condenser Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.