E14
Grundig Interior LED Lighting Circuit Fault

E14 error displayed, often with the interior light not working or flickering.

Advertisements

Possible Causes

Failed LED module, Faulty LED driver circuit on main PCB, Loose light connector, Damaged wiring in door or cabinet

How to Fix / Troubleshooting

Safety first: Unplug the freezer before working on lighting components.

Steps:

  • Access LED module: Remove the light cover inside the freezer (usually clipped or screwed).
  • Check connections: Ensure the LED module connector is firmly seated.
  • Test LED module: If possible, test the LED module with a suitable low-voltage DC source (if it is a low-voltage module) or check continuity according to the service manual. Replace if non-functional.
  • Inspect wiring: Look for pinched or broken wires leading to the light.
  • Driver circuit: If the LED module and wiring are good, the LED driver on the main PCB may be faulty, requiring PCB replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Interior LED Light Module
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements