E2
Grundig
Evaporator Temperature Sensor (NTC) Fault
Display shows E2, freezer may overcool, undercool, or cycle erratically.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed evaporator NTC sensor, Sensor wiring damaged by ice buildup, Loose connector at main control PCB, Sensor out of position on evaporator coil
How to Fix / Troubleshooting
Safety first: Disconnect mains power before removing panels or working near wiring.
How to check:
- Access the evaporator: Empty the freezer drawers/shelves. Remove the rear interior panel of the freezer (usually held by screws and clips). If it is iced over, allow the unit to defrost fully before forcing the panel off.
- Locate the evaporator sensor: It is typically clipped to the evaporator coil or attached to the coil with a metal clip or plastic holder.
- Inspect the sensor and cable: Look for damage to the insulation, signs of crushing by ice, or a sensor that has fallen away from the coil.
- Measure resistance: Disconnect the sensor from its connector and measure resistance with a multimeter. Compare to the expected NTC value for the approximate temperature (e.g., at 0°C many NTCs are around 12–30 kΩ). If open or shorted, replace.
- Reattach or replace: If the sensor is intact but out of position, re-clip it firmly to the evaporator. If faulty, install a new Grundig evaporator NTC sensor and secure it in the same location.
- Reassemble and test: Refit the rear panel, restore power, and monitor for correct operation and disappearance of E2.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Evaporator NTC Sensor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements