E6
Grundig
Main Control PCB Failure
E6 error displayed, interior light and display may work but compressor does not run or runs erratically.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed relay or triac on main control PCB, Burnt PCB tracks due to surge, Internal microcontroller fault, Corroded PCB from moisture ingress
How to Fix / Troubleshooting
Safety first: Disconnect mains power before accessing the control board. Capacitors on the PCB may hold charge briefly after unplugging.
Procedure:
- Access main PCB: On many Grundig freezers the main board is located in a rear lower compartment or behind a top control cover. Remove the appropriate panel.
- Visual inspection: Look for burnt components, darkened areas, cracked solder joints, or swollen capacitors.
- Check connectors: Ensure all harness connectors are fully seated and free of corrosion.
- Relay test (basic): If you are experienced, you can test continuity across relay contacts (with power off) and check coil resistance. However, most PCB faults are resolved by replacement rather than component-level repair.
- Replace PCB: If there is clear damage or E6 persists after checking sensors and wiring, replace the main control PCB with the exact Grundig part number. Transfer any jumper settings or configuration plugs as per service documentation.
- Reassemble and test: Refit covers, restore power, and verify normal operation and that E6 no longer appears.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Control PCB
Check Price on Amazon
We may earn a commission from links on this page.