Grundig Control System Not Calling for Cooling

Freezer interior light works but compressor and fan do not run, no cooling.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty thermostat or temperature sensor, Stuck relay on main PCB, Control board logic failure, Door switch stuck in open position (some models inhibit cooling with door open)

How to Fix / Troubleshooting

Safety first: Unplug the freezer before accessing controls.

Steps:

  • Check temperature setting: Ensure the freezer is not set to OFF or a high temperature that prevents cooling.
  • Door switch: Press and release the door switch manually. If the interior light does not respond correctly, replace the door switch.
  • Sensor test: Measure the freezer NTC sensor resistance. Replace if faulty.
  • Control board: If sensors and door switch are good but the compressor never receives power, the main PCB relay may be defective. Replace the main control PCB.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Main Control PCB
Check Price on Amazon