Grundig Temperature Sensing / Calibration Issue

Freezer temperature display inaccurate compared to a separate thermometer.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Aging or out-of-tolerance NTC sensor, Poor sensor placement or contact with liner, Control board calibration drift, Thermometer placement error

How to Fix / Troubleshooting

Safety first: Unplug the freezer before accessing sensors.

Steps:

  • Verify with reliable thermometer: Place a quality freezer thermometer in the middle of the compartment away from walls and wait several hours.
  • Check sensor: Test the freezer NTC sensor resistance and compare to the manufacturer's curve. Replace if significantly out of tolerance.
  • Sensor placement: Ensure the sensor is correctly clipped to the liner or evaporator as designed, not hanging loose.
  • Control board: If the sensor is correct but readings remain inaccurate, the main PCB may have calibration issues and may need replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Freezer NTC Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements