Haier Display / Sensor Reading Error

Digital display shows dashes or unrealistic temperatures (e.g., 88°C) but freezer seems to cool.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose display connector, Faulty temperature sensor, Display PCB malfunction, Electrical noise on sensor lines

How to Fix / Troubleshooting

Safety first: Disconnect power before accessing the control panel.

  • Reseat connectors: Remove the control panel and reseat the display and sensor connectors.
  • Test sensors: Measure resistance of cabinet and freezer NTC sensors and replace any that are out of spec.
  • Inspect display PCB: Look for corrosion or damage. Replace the display board if readings remain erratic with good sensors.
  • Check grounding: Ensure the freezer's ground connection is secure to reduce electrical noise.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Display PCB
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements