Haier Control Board Output Failure

Display works but compressor and fans do not run.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed relay on main PCB, Burned PCB trace, Software lockup, Safety sensor preventing start

How to Fix / Troubleshooting

Safety first: Unplug the freezer before removing the control board cover.

  • Power reset: Unplug for 10 minutes and plug back in to clear any temporary lockup.
  • Check sensors: Faulty temperature or defrost sensors can prevent compressor start. Test NTC sensors and replace any that are out of spec.
  • Inspect PCB: Look for burnt relays or darkened areas on the main control board. If found, replace the board.
  • Relay test: A qualified technician can test whether the compressor relay is energizing when cooling is demanded. If not, replace the main PCB.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control PCB
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements