E6
Haier Main Control Board Fault / Internal Error

Freezer shows E6, may not start compressor or may shut down unexpectedly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed microcontroller on main PCB, Power supply section failure on PCB, Corrupted firmware, Shorted component on control board

How to Fix / Troubleshooting

Safety first: Unplug the freezer. The control board area may have exposed mains voltage terminals—do not touch while energized.

  • Power cycle: Disconnect power for at least 10 minutes to discharge capacitors. Plug back in and check if E6 clears. If it returns, proceed.
  • Access main PCB: Remove the rear lower service panel or side panel (model dependent) to expose the main control board enclosure.
  • Visual inspection: Look for burnt components, bulging capacitors, or darkened areas on the PCB. Check for insect infestation or corrosion.
  • Check connectors: Reseat all harness connectors firmly. Ensure the ground wire is secure to the chassis.
  • Measure supply voltage: With the unit plugged in (only if you are trained and equipped), verify correct AC input to the board and correct low-voltage DC outputs. If voltages are missing or unstable, the board is defective.
  • Replace board: If E6 persists and no external wiring faults are found, replace the main control PCB with the exact Haier part number. Transfer any jumper settings or wiring positions exactly as original.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control PCB
Check Price on Amazon