F5
Haier Condenser Fan Motor Fault

Freezer shows F5 and may not cool or may run continuously.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Seized condenser fan motor, Fan blade obstructed by debris, Open fan motor winding, Faulty fan driver circuit on main PCB

How to Fix / Troubleshooting

Safety first: Unplug the freezer before working near the condenser and fan.

  • Locate condenser fan: Typically mounted near the compressor, blowing air across the condenser coils.
  • Check for obstructions: Remove any dust, plastic, or wiring that may be blocking the fan blade. Spin the blade by hand; it should move freely.
  • Test motor: Disconnect the fan motor and measure resistance across its terminals. An open circuit indicates a failed motor.
  • Replace fan motor: Remove mounting screws, transfer the fan blade to the new motor, and reinstall. Ensure correct airflow direction.
  • Control board check: If the motor tests good but does not receive voltage when the compressor runs, the main control PCB fan output may be defective and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Condenser Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements