Hisense
Door Switch Stuck or Misaligned
Freezer interior light stays on even when the door is closed, causing warming and condensation near the light.
Advertisements
Possible Causes
Faulty door switch contacts, Switch plunger not fully depressed by door, Broken switch mounting bracket, Control board not turning light off
How to Fix / Troubleshooting
Safety first: Unplug the freezer before working on the door switch or light circuit.
- Check light status: Press the door switch manually with the door open. The light should turn off. If it stays on, the switch or control is faulty.
- Inspect switch alignment: Ensure the door contacts the switch plunger fully when closed. Adjust the switch position if possible.
- Test switch: Remove the switch and test continuity with a multimeter. Replace if it does not change state when pressed.
- Control issue: If a new switch does not fix the problem, the main control board may be stuck powering the light circuit.
A light that stays on can significantly warm the cabinet; correct this issue promptly to protect food.
Advertisements
Repair Difficulty
Easy
2/5