d2
Hitachi Defrost Duration / Termination Error

Freezer displays d2 and may remain in defrost too long or not enter defrost

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defrost thermostat stuck open or closed, Incorrect evaporator thermistor reading, Faulty main control PCB defrost algorithm

How to Fix / Troubleshooting

Safety first: Unplug the freezer before accessing the evaporator area.

  • Inspect defrost thermostat: Locate the defrost thermostat on the evaporator. Test for continuity at freezing temperature; it should be closed when cold.
  • Check evaporator thermistor: See F3 for testing procedure. Replace if readings are out of range.
  • Verify heater operation: During a forced defrost (if available), confirm the heater warms the evaporator. Lack of heating may confuse the control.
  • Replace faulty components: Install a new Hitachi defrost thermostat or thermistor as needed.
  • Control PCB: If all defrost components test good, replace the main control PCB to correct d2 errors.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Defrost Thermostat
Check Price on Amazon