H4
Hitachi Inverter / Compressor Drive Fault (for inverter-type Hitachi freezers)

Freezer shows H4 and may stop cooling or enter a protective shutdown

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty inverter PCB, Incorrect DC supply from main control PCB, Shorted compressor windings, Loose inverter-compressor wiring

How to Fix / Troubleshooting

Safety first: Unplug the freezer. Inverter circuits can store high voltage; do not touch capacitors or power components immediately after unplugging.

  • Inspect inverter PCB: Locate the inverter module near the compressor. Check for burnt components, cracked solder joints, or bulging capacitors.
  • Check wiring: Ensure all connectors between the main control PCB, inverter PCB, and compressor are fully seated and undamaged.
  • Test compressor windings: With the inverter disconnected, measure resistance between compressor terminals. Shorted or open windings indicate a failed compressor.
  • Replace inverter PCB: If the compressor tests good and wiring is intact, replace the Hitachi inverter PCB.
  • Technician recommended: Due to high voltages and specialized diagnostics, inverter faults are best handled by an authorized Hitachi technician.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Inverter PCB
Check Price on Amazon