Hoover Fast-Freeze Circuit / Control Fault

Fast-freeze function does not activate or indicator does not light, although basic cooling works.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty fast-freeze button or switch, LED indicator failure, Main PCB not entering fast-freeze mode, Wiring fault between UI and PCB

How to Fix / Troubleshooting

Safety: Unplug the freezer before accessing the control panel.

  • Check indicator: Press the fast-freeze button and listen for a change in compressor sound. If the function works but the light does not, the LED may be faulty.
  • Test button: On mechanical models, test the fast-freeze switch for continuity when pressed. Replace if open.
  • Inspect wiring: Ensure the fast-freeze button wiring or ribbon cable is securely connected to the main PCB.
  • PCB function: If the button and wiring are good but the mode never engages, the main control board may be faulty and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Control Panel / Keypad Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements