Hoover Interior Light Circuit Fault

Freezer interior light not working but cooling is normal.

Advertisements

Possible Causes

Blown interior lamp, Faulty door switch, Loose lamp holder connection, Failed LED module

How to Fix / Troubleshooting

Safety: Unplug the freezer before changing bulbs or working on the light circuit.

  • Check bulb: Remove the light cover (usually clipped or screwed). Inspect the bulb for a broken filament or darkened glass. Replace with the correct wattage or LED type specified by Hoover.
  • Test door switch: Press the door switch manually and see if the light flickers. If not, test the switch for continuity and replace if faulty.
  • Inspect lamp holder: Check for loose wires or signs of heat damage at the lamp holder. Tighten connections as needed.
  • LED modules: On models with LED lighting, the entire LED light module may need replacement if it has failed.
Advertisements

Repair Difficulty

Very Easy 1/5

Required Part

Interior Light Bulb
Check Price on Amazon