Hoover Poor Cooling / Partial Loss of Refrigeration

Freezer runs continuously but does not reach set temperature (stays around -5 to 0 °C).

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Low refrigerant charge from small leak, Partially blocked capillary tube, Inefficient or worn compressor, Condenser coil heavily clogged with dust

How to Fix / Troubleshooting

Safety: Unplug the freezer before cleaning or removing panels. Do not pierce or bend refrigerant pipes.

  • Clean condenser: Pull the freezer away from the wall and clean the rear condenser coil thoroughly with a brush and vacuum. Ensure good airflow around the unit.
  • Check door gasket: Inspect the door seal for gaps, tears, or hardened sections. Close a sheet of paper in the door at various points; it should grip firmly.
  • Check frost pattern: Remove the internal rear panel and observe the evaporator after 15–20 minutes of running. An even frost across most of the coil is normal; frost only on a small section suggests a sealed-system issue.
  • Monitor temperature: After cleaning and checking seals, allow 24 hours. If the freezer still cannot reach -18 °C, a refrigerant or compressor problem is likely.

Important: Low gas or a blocked capillary must be repaired by a certified refrigeration technician. Do not attempt to recharge the system yourself.

Advertisements

Repair Difficulty

Hard 4/5