F15
Hotpoint Evaporator Thermistor Range/Calibration Error

Freezer shows sensor error, frost pattern uneven, some sections warm

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect replacement thermistor installed, Thermistor out of calibration, Poor thermal contact with evaporator, Control board misinterpreting sensor signal

How to Fix / Troubleshooting

Safety first: Disconnect power before accessing the evaporator area.

Steps:

  • Access evaporator: Remove interior rear panel to expose the evaporator and thermistor.
  • Verify part number: Check that the installed thermistor matches the correct Hotpoint part number for your model. Using a generic or wrong-value sensor can cause range errors.
  • Check mounting: Ensure the thermistor is firmly clipped to the correct coil location and not hanging in free air.
  • Test resistance vs. temperature: Measure thermistor resistance at a known temperature (e.g., place the sensor tip in ice water and compare reading to expected value from a service chart if available).
  • Replace if suspect: Install a new OEM thermistor with proper value and secure it to the evaporator.
  • Control board check: If a correct sensor still reads wrong, the main board's ADC circuit may be faulty and require board replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Evaporator Thermistor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements