E1
Ikea
General Sensor Error (Model-Dependent)
Freezer shows E1 and may not maintain correct temperature.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Any of the NTC sensors out of range, Loose sensor connector, Damaged wiring harness, Faulty control board analog input
How to Fix / Troubleshooting
Safety: Disconnect power before testing sensors or removing panels.
Steps:
- 1. Consult model label: On some IKEA models, E1 is a generic sensor error. Check the user manual or service sheet (often behind the rear panel) for exact mapping.
- 2. Test all accessible sensors: Freezer compartment NTC, ambient/cabinet NTC, and evaporator NTC. Compare resistance readings to expected values at known temperatures.
- 3. Inspect harness: Follow sensor wires from the cabinet to the control board, checking for pinched or broken sections.
- 4. Reseat connectors: Unplug and reconnect all sensor plugs at the board to ensure good contact.
- 5. Replace faulty sensor or board: If a sensor is out of spec, replace it. If all sensors test correctly, the control board may be misreading and should be replaced.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Freezer NTC Temperature Sensor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements