E3
Ikea
Evaporator Fan Motor Error
Freezer shows E3 and the fan may not run or may run erratically.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed evaporator fan motor, Ice blocking fan blades, Broken fan wiring, Faulty control board fan driver
How to Fix / Troubleshooting
Safety: Unplug the freezer before accessing the fan area.
Steps:
- 1. Access fan: Remove baskets and the inner rear panel to expose the evaporator fan assembly.
- 2. Check for ice: Look for ice build-up around the fan shroud or blades. If present, allow the freezer to defrost fully (doors open, towels in place) before further testing.
- 3. Spin the fan: Gently turn the blades by hand. They should spin freely without rubbing.
- 4. Test motor: Disconnect the fan and measure resistance across the motor terminals. An open circuit indicates a failed motor.
- 5. Inspect wiring: Check the harness from the fan to the control board for damage.
- 6. Replace fan motor: Install a new evaporator fan motor assembly compatible with your IKEA model, ensuring correct orientation and secure mounting.
- 7. If E3 persists: The control board’s fan driver circuit may be faulty and require board replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Evaporator Fan Motor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements