E8
Ikea Calibration / Sensor Range Error

Freezer shows E8 and may have unstable or incorrect temperature readings.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Sensor reading out of expected range, Incorrect sensor type fitted, Control board firmware issue, Poor sensor placement after repair

How to Fix / Troubleshooting

Safety: Unplug before testing sensors.

Steps:

  • 1. Verify sensor type: Ensure any previously replaced NTC sensors are the correct part number for the IKEA model.
  • 2. Check sensor placement: Sensors must be clipped firmly to the evaporator or wall as designed; loose sensors can misread temperatures.
  • 3. Test resistance: Compare sensor readings at known temperatures (e.g., ice water ~0°C) to manufacturer specs.
  • 4. Replace incorrect or faulty sensors: Install correct OEM sensors and route wiring properly.
  • 5. Control board: If sensors are correct and E8 persists, the board may require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Freezer NTC Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.