LO
Ikea Temperature Regulation / Thermostat Calibration Fault

Display shows LO or a very low temperature indication; food may be over-frozen and ice forming excessively.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck relay on control board, Shorted temperature sensor, Incorrect temperature setting, Faulty user interface sending wrong setpoint

How to Fix / Troubleshooting

Safety: Unplug the freezer before removing any control covers.

Steps:

  • 1. Verify settings: Check that the temperature is not set to the coldest setting or to a special fast-freeze mode. Adjust to the recommended setting (usually around -18°C).
  • 2. Power reset: Unplug for 5–10 minutes, then reconnect and recheck the display.
  • 3. Check sensors: If the freezer continues to run excessively cold, the temperature sensor may be shorted. Follow the sensor testing steps similar to F1 (freezer NTC) and replace if resistance is abnormally low.
  • 4. Inspect control board: A stuck compressor relay can keep the compressor running continuously. Access the main board and look for signs of overheating around the relay. Replacement of the board is usually required if the relay is stuck.

Note: Extremely low temperatures can damage some foods; adjust settings promptly.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Freezer NTC Temperature Sensor
Check Price on Amazon