Ikea
No Start / Control or Power Circuit Issue
Freezer interior light works but compressor and fan do not start; no humming sound.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty main control board, Defective thermostat or temperature control, Open thermal fuse in wiring, Loose mains connection
How to Fix / Troubleshooting
Safety: Unplug before removing any covers.
Steps:
- 1. Confirm outlet power: Test the wall outlet with another appliance.
- 2. Check control settings: Ensure the freezer is not in an off or demo mode and that the temperature is set correctly.
- 3. Inspect wiring at terminal block: Tighten any loose connections and look for burnt wires.
- 4. Check thermal fuse (if fitted): Some IKEA freezers have a thermal fuse in series with the compressor circuit. Test for continuity and replace if open.
- 5. Replace control board: If power is present and safety devices are intact but the compressor and fan never receive power, the main control board is likely faulty.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Electronic Control Board
Check Price on Amazon
We may earn a commission from links on this page.