Possible Causes

Failing compressor, Loose compressor mounting springs, Faulty start relay causing repeated starts, Refrigerant lines vibrating against cabinet

How to Fix / Troubleshooting

Safety: Unplug before touching the compressor or tubing.

Steps:

  • 1. Isolate noise source: Listen at the rear to confirm the noise is from the compressor area, not the fan.
  • 2. Check mounting: Ensure the compressor mounting grommets and springs are intact and that the compressor is not touching the cabinet directly.
  • 3. Inspect tubing: Look for copper lines touching each other or the cabinet. Gently bend them apart slightly to stop vibration, taking care not to kink or crack them.
  • 4. Start relay: If the compressor hums briefly then clicks off repeatedly, replace the PTC start relay and capacitor (if fitted).
  • 5. Compressor condition: If noise persists and cooling is poor, the compressor may be failing and require professional replacement.
Advertisements

Repair Difficulty

Hard 4/5