Ikea
Mechanical Vibration / Loose Components
Freezer makes loud rattling or knocking noises, especially when the compressor starts or stops.
Advertisements
Possible Causes
Loose internal panels or baskets, Condenser or evaporator fan blades hitting shroud, Refrigerant lines rattling, Loose compressor mounts
How to Fix / Troubleshooting
Safety: Unplug before adjusting internal or rear components.
Steps:
- 1. Check inside: Remove baskets and ensure no items are touching the evaporator cover or fan area.
- 2. Inspect fan blades: Access the evaporator and condenser fans and check that blades are not rubbing against housings. Adjust shrouds or replace damaged fans.
- 3. Tighten panels: Ensure all internal and external panels and screws are tight.
- 4. Adjust tubing: Gently reposition any refrigerant lines that rattle against the cabinet.
- 5. Compressor mounts: Replace worn rubber grommets if the compressor is knocking against its base.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Evaporator Fan Motor / Condenser Fan Motor
Check Price on Amazon
We may earn a commission from links on this page.