AL03
Indesit
Door Open Alarm / Door Switch Mis-detection
Freezer shows AL03 and the door alarm sounds even when the door appears closed.
Advertisements
Possible Causes
Misaligned door, Damaged door gasket, Faulty door switch or reed sensor, Weak or missing door magnet
How to Fix / Troubleshooting
Safety first: Ensure the appliance is stable before adjusting the door.
Door and gasket checks:
- Inspect the door gasket all around for splits, hardened sections, or areas not touching the cabinet.
- Close the door on a strip of paper at several points; you should feel resistance when pulling it out. If it slides out easily, the seal is poor.
- Level the freezer using the adjustable feet so the door closes by itself from a partially open position.
Switch and magnet:
- Locate the door switch or magnetic sensor and ensure it is firmly mounted.
- Check that the magnet in the door (if used) is present and aligned with the sensor.
- Test the switch with a multimeter and replace if it does not change state when the door is opened/closed.
Advertisements
Repair Difficulty
Easy
2/5