Indesit Poor Cooling – Long Run Time

Freezer runs but does not reach set temperature; food is soft or partially thawed.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Dirty condenser coils, Failing compressor, Low refrigerant charge due to leak, Door gasket leaking warm air

How to Fix / Troubleshooting

Safety first: Unplug the appliance before cleaning the condenser.

Steps:

  • Pull the freezer away from the wall and locate the condenser at the rear or underneath.
  • Clean dust and lint from the condenser using a soft brush and vacuum.
  • Inspect the door gasket for gaps or damage; clean and replace if it does not seal properly.
  • Ensure the freezer has adequate ventilation space around it and is not installed in a very hot environment.

If cooling is still poor: A weak compressor or refrigerant leak may be present. These sealed-system issues require a qualified technician with refrigeration tools.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Condenser Coil
Check Price on Amazon