Possible Causes

Compressor oil displaced into refrigerant lines, Tilted transport, Overload protector tripping

How to Fix / Troubleshooting

Safety first: Do not attempt to force the compressor to start repeatedly.

Steps:

  • If the freezer was transported on its side or tilted, leave it upright and unplugged for at least 4–6 hours (24 hours if heavily tilted) to allow compressor oil to settle.
  • After the rest period, plug in and check if the compressor starts normally.
  • If it still fails to start, follow compressor start diagnostics (relay, overload, control board) as described in other entries.