Insignia
Display Module Failure
Display is completely blank but interior light works and freezer seems to cool normally.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed display PCB, Loose display connector, Damaged display cable, Main control board display output failure
How to Fix / Troubleshooting
Safety first: Unplug the freezer before accessing the display or control housing.
Steps:
- Access display: Remove the screws holding the display/control housing and gently lower it.
- Check connectors: Ensure the display module connector is fully seated on the display PCB and main board.
- Inspect for damage: Look for burnt or cracked components on the display board.
- Replace display: If wiring is intact, replace the display module or entire control panel assembly.
- Control board: If a new display does not light, the main control board may be defective.
Note: Cooling can continue even with a failed display, but you will not be able to adjust settings.
Advertisements
Repair Difficulty
Medium
3/5