Insignia Interior Light Circuit Failure

Freezer interior light does not turn on when door is opened, but cooling is normal.

Advertisements

Possible Causes

Burned-out LED module or bulb, Faulty door switch, Loose light wiring connector, Failed light driver on control board

How to Fix / Troubleshooting

Safety first: Unplug the freezer before replacing bulbs or accessing wiring.

Steps:

  • Check door switch: Verify that the switch actuates properly. If the control panel responds to door opening (e.g., fan stops), the switch is likely good.
  • Inspect light assembly: Remove the light lens and check for a replaceable bulb or LED module. Replace the LED light module or bulb if visibly burned or darkened.
  • Check wiring: Ensure the light connector is firmly seated.
  • Control board: If the light and wiring are good, the main control board may not be supplying power to the light circuit.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

LED Light Module
Check Price on Amazon