F2
JennAir Overtemperature Safety / Sensor Out-of-Range Fault

Display shows F2, audible alarm may sound, freezer may shut down cooling as a safety precaution.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Thermistor reading extreme temperature due to failure, Wiring short to line or neutral, Control board misreading sensor, Actual extreme overtemperature event

How to Fix / Troubleshooting

Safety first: Unplug the freezer. If there is any burning smell or visible smoke, do not restore power and contact a professional immediately.

  • Step 1 – Verify actual temperature: Use a separate thermometer to check the real freezer temperature. If it is near normal, the sensor reading is likely faulty.
  • Step 2 – Inspect thermistor wiring: Look for melted insulation or wires touching hot components.
  • Step 3 – Replace suspect thermistor: If the freezer thermistor is discolored or tests out of range, replace it.
  • Step 4 – Reset and monitor: Restore power and monitor operation. If F2 returns quickly, the control board may be defective and should be replaced by a technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Freezer Thermistor
Check Price on Amazon