Leisure
User Interface Keypad Failure
Control panel buttons unresponsive; cannot change temperature or modes.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Worn or damaged touch buttons, Moisture ingress into control fascia, Loose ribbon cable to display PCB, Failed display PCB
How to Fix / Troubleshooting
Safety: Unplug the freezer before removing the control panel.
Steps:
- 1. Inspect fascia: Check for cracks or signs of liquid spills on the control panel.
- 2. Access display PCB: Remove the fascia and inspect the keypad contacts and ribbon cable.
- 3. Reseat cable: Disconnect and reconnect the ribbon cable to ensure good contact.
- 4. Dry moisture: If condensation is present, dry thoroughly before reassembly.
- 5. Replace display PCB: If buttons remain unresponsive, install a new Leisure display PCB / user interface board.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Display PCB / User Interface Board
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements